Edge Computing Applications Use Device Level Cooling to Ensure Performance and Reliability

Edge computing devices are often installed environmentally severe and/or remote locations where reliable, long-term operation is essential. It is critical to thermally manage the CPUs, FPGAs, GPUs and other processing devices housed inside. Active cooling from ATS fanSINKs provides the cooling airflow continuously needed at the device level.

fanSINKs feature cross-cut, straight fins that maximize fan airflow for more efficient cooling. They are available for component packages from 27mm-84mm. Depending on their size, fanSINKs can be securely clipped onto a device with the ATS maxiGRIP attachment system, or with PEM screws or push pin hardware for direct attachment to the PCB. Smaller fanSINKs attach with maxiGRIP’s high performance plastic frame clip and 300 series stainless steel spring clip. The secure maxiGRIP attachment eliminates the need to drill holes in the PCB. Larger size fanSINKs fit tightly on components and attach firmly to the PCB with standoff and spring hardware.

Edge computing devices are often installed environmentally severe and/or remote locations where reliable, long-term operation is essential. It is critical to thermally manage the CPUs, FPGAs, GPUs and other processing devices housed inside. Active cooling from ATS fanSINKs provides the cooling airflow continuously needed at the device level. fanSINKs feature cross-cut, straight fins that maximize fan airflow for more efficient cooling. They are available for component packages from 27mm-84mm.

fanSINKs are pre-assembled with Chomerics T-412 thermal adhesive tape (smaller sizes), or with Chomerics T-766 phase change thermal interface material (larger sizes). These proven interface materials increase heat flow into the sinks to maximize cooling performance. Fans for use with fanSINKs are customer specified and provided.

fanSINKS can be purchased via ATS’s global distribution network, including Mouser and Digi-Key and Sager. Also, Sager provides customer specific value add of fans to meet customer application requirements.

==> Learn about our Edge Computing and Appliance fanSINKS at ATS’s website

fanSINK Line Expanded by ATS, Footprints Now 27mm x 84mm

Does your design need cooling for hot components not getting enough air or have components that simply need spot cooling?

The ATS fanSINK line is now available in sizes from 27mm to 84mm. Engineers can now easily add industry leading thermal management across a very wide set of component footprints.

Available from ATS distribution partners now or learn more at:
* Video (1:48) https://www.youtube.com/watch?v=uCRvNPI8clk
* Website: https://www.qats.com/eShop.aspx?productGroup=0&subGroup=2&q=fanSINK

Webinar on Fan Characterization

Advanced Thermal Solutions, Inc. (ATS) is hosting a series of monthly, online webinars covering different aspects of the thermal management of electronics. This month’s webinar will be held on Thursday, Jan. 24 from 2-3 p.m. ET and will cover fan characterization and deployment in an electronics system. Learn more and register at https://qats.com/Training/Webinars.

Effective cooling of high-powered CPUs on dense server boards

By Norman Quesnel
Senior Member of Marketing Staff
Advanced Thermal Solutions, Inc. (ATS)

The main goal of electronics thermal management is to efficiently remove enough heat from a device’s active region so that it stays within its rated temperature. Providing effective cooling presents different design challenges, not all of which involve the chip itself. Some thermal challenges are related to the system in which the chip resides. A common example is cooling a device positioned on a crowded printed circuit board (PCB). The congestion of components restricts airflow and space, which makes the use of many conventional cooling devices difficult.

Dense Server boards

Figure 1. A dense motherboard from Gigabyte Technologies featuring an Intel P55 chipset. [1]

Optimizing PCB for thermal management has been shown to ensure reliability, speed time to market and reduce overall costs. With proper design, all semiconductor devices on a PCB will be maintained at or below their maximum rated temperature. Applying thermal management can sometimes be problematic for dense boards employing fine pitch devices. (Pitch is the space between the center of one BGA ball to the center of the next one.)

But if certain layout guidelines are not followed and considerations are not given to a PCB’s thermal performance, the device and the overall system can suffer from sub-par performance and reliability in the field. [2]

Today’s circuit boards are often assembled with increasing density with the goal of making smaller, lighter systems, or to provide more processing power in demanding applications such as data centers and IoT (Internet of Things) applications. PCB designers must use proven layout techniques to ensure effective thermal performance for the board and its components.

Figure 2. Crowded boards have limited space from where chip cooling air can be drawn. (Wikimedia Commons)

Part of the trend toward higher density boards is related to the industry’s adoption of increased server density. This means increasing the power of the chips, putting more chips per rack unit, and filling up the racks as much as possible. Rack power has transitioned from a normal of about 4 kilowatts to 70 kilowatts per rack.

High current electronic components like microcontrollers can generate a significant amount of heat. To keep the board temperature lower, it is usually best to mount these components near the center of the board. Heat can diffuse throughout the board and the temperature of the board will be lower.

Many components in this situation, such as GPU, will require a dedicated cooling system, such as a fan sink. But simply installing a fan sink on top may not provide the needed level of cooling. It is good practice to quantify system flow bypass on the fan sink, and to also consider the proximity of components neighboring the fan sink. The mass airflow rate is the true measure of available coolant, along with the air velocity.

Obstructions in the intake or exhaust of the fan (e.g. neighboring components) must be carefully considered as their presence will impact the performance of the fan sink. The size and position of adjacent components can impact the fan’s performance. [3]

Figure 3. The QuadFlow CPU cooler draws air from four sides, passing it through cooling fins and expelling warm air. (Advanced Thermal Solutions, Inc.)

One new and effective solution for cooling hot components on congested PCBs is the QuadFlow CPU cooler from Advanced Thermal Solutions, Inc. (ATS). The liquid-free cooler features a high-power blower that draws in air from four different directions. So, while proximate components may block local air in a couple of directions, the QuadFlow fin fields will pull in air from the other directions to make sure that the component is being cooled.

QuadFlow coolers are just 29 mm tall, so they will fit into standard 1-U racks and there are several options for base material (aluminum, copper, or vapor chamber) depending on performance, weight, or cost requirements. [4]

Before applying any thermal management hardware, the smartest engineering activity may be investing is various PCB design services. These include CFD studies on boards at the CAD stage to wind-tunnel testing of actual or dummy boards in conditions that simulate air distribution in real-world applications. Services are available for characterizing boards using research-quality instruments, heat and air velocity sensors, and PCs.

Figure 4. FloTHERM image reveals hotter and cooler regions on a PCB. (Advanced Thermal Solutions, Inc.)

Dummy or working PCBs can be tested in isolation or installed in their own packaging domain. Computational simulations can be made of engineered designs using computational fluid design packages such as 6SigmaET, FloTHERM and CFDesign.

These services are available from ATS, whose engineers can design board layouts to improve cooling airflow in dense systems. Natural airflow can be enhanced to individual hot components and to active cooling systems that rely on airflow for effective performance. Often, these studies head off more expensive cooling solutions by showing that minor changes to component layouts or to the volume of airflow will resolve thermal problems. [5]

References
1. https://www.techpowerup.com/103375/gigabyte-unwraps-latest-p55-series-motherboards
2. https://www.embedded.com/design/configurable-systems/4395845/Ultra-fine-pitch-devices-pose-new-PCB-design-issues
3. https://www.hpe.com/us/en/insights/articles/why-youll-be-using-liquid-cooling-in-five-years-1710.html
4. https://www.qats.com/cms/2013/06/21/how-system-flow-affects-fan-sink-performance/
5. https://www.qats.com/Consulting/PCB-Board-Layout

Advanced Thermal Solutions, Inc. (ATS) is hosting a series of monthly, online webinars covering different aspects of the thermal management of electronics. On Thursday, Jan. 29 from 2-3 p.m. ET the webinar will cover “Methodologies for Fan Characterization and Deployment within a System.” Learn more and register at https://qats.com/Training/Webinars.

For more information about Advanced Thermal Solutions, Inc. (ATS) thermal management consulting and design services, visit https://www.qats.com/Consulting/Custom-Cooling-Solutions or contact ATS at 781.769.2800 or ats-hq@qats.com.

Analysis of Fan Curves and Fan Laws in Thermal Management of Electronics

This is the second installment in a two-part series examining the use of fans in the thermal management of electronics. Part one, which can be found at https://www.qats.com/cms/2017/03/06/utilizing-fans-thermal-management-electronics-systems, took a closer look at the common types of fans and blowers and the factors that engineers should consider when picking a fan.

In part two, basic fan laws will be explored, as well as using fan curves to analyze fan performance in a system. These standard calculations can help engineers establish boundary conditions for air velocity and pressure drop and ensure that these will meet the thermal requirements (e.g. ambient and junction temperature) of the system.

Fan Laws

CFD simulations of air velocity in a system with fans drawing air across high-powered components. Utilizing fan curves and fan laws enabled ATS engineers to establish the parameters for a successful use of fans for cooling this system. (Advanced Thermal Solutions, Inc.)

FAN LAWS

As noted by Mike Turner of Comair Rotron in “All You Need to Know About Fans,” the primary principle for determining whether or not a fan work within a particular system is that “any given fan can only deliver one flow at one pressure in a particular system.” Each fan has a specific operating point that can be discovered on the fan curve at the intersection of fan static pressure curve and the system pressure curve. Turner advises, “It is best to select a fan that will give an operating point being toward the high flow, low pressure end of the performance curve to maintain propeller efficiency and to avoid propeller stall.”

Before getting to the fan curve though, engineers must run through basic calculations to understand the conditions of the systems in which the fans will be placed. The three basic fan laws, according to Eldridge USA, are as follows:

Fan Laws

While those fan laws will tell you about the specific fans, it is also critical to examine the system in which the fans will be operating. Among the equations that can be used to characterize a system are Volumetric Flow Rate, Mass Flow Rate, Pressure, Power, and Sound (equations are listed below).

Fan Laws

A Qpedia Thermal eMagazine article entitled, “How to Use Fan Curves and Laws in Thermal Design,” added:

“Published fan laws apply to applications where a fan’s air flow rate and pressure are independent of the Reynolds number. In some applications, however, fan performance is not independent and thus the change in Reynolds number should be incorporated into the equation. To determine if the Reynolds number needs to be considered, it must first be calculated.

“According to AMCA specifications, an axial fan’s minimum Reynolds number is 2.0×106. When the calculated Reynolds number is above this value, its effects can be ignored.”

The equation to calculate the Reynolds number is as follows:

Fan Law

In an “Engineering Letter” from The New York Blower Company, it was explained that fan laws only work “within a fixed system with no change in the aerodynamics or airflow characteristics of the system.” In the case of electronics cooling, in which the system requirements will be mostly consistent (with margins for error in case of max power usage), these laws will govern the capabilities of the fans to provide the necessary forced convection cooling for the components in the system.

The Engineering Letter continued, “During the process of system design, the fan laws can be helpful in determining the alternate performance criteria or in developing a maximum/minimum range.” A Qpedia article entitled, “Designing Efficient Fans for Electronics Cooling Applications,” added, “As a general rule, fan efficiency increases with blade diameter and rotational speed.”

There are tools that can assist engineers in the calculation of these basic fan laws, including fan calculators, such as the one provided by Twin City Fans & Blowers.

ANALYZING FAN CURVES AND FAN PERFORMANCE

The aerodynamics of a fan can be charted in a fan curve, which displays the static pressure of the system dependent on the amount of air flow. As Turner noted, fan curves are read from right to left, beginning “with healthy aerodynamic flow and follow it through to aerodynamic stall.” Turner continued, “It is best to select a fan that will give an operating point being toward the high flow, low pressure end of the performance curve to maintain propeller efficiency and to avoid propeller stall.”

Fan Laws

An example of a basic fan curve with static pressure on the Y-axis and airflow on the X-axis. Fan curves are read from right to left beginning with healthy airflow.

There are means for testing fan curves, such as the FCM-100 Fan Characterization Module (pictured below) from Advanced Thermal Solutions, Inc. (ATS). The FCM-100 is specially designed with flow restriction plates that allow the user to control pressure drop across the system during testing. Used in conjunction with pressure and velocity measurement equipment, it verifies manufacturer performance data.

Fan Laws

The ATS FCM-100 Fan Characterization Module is a specialized unit designed to test and characterize fans of various sizes and performance outputs. (Advanced Thermal Solutions, Inc.)

The Qpedia article on fan curves explained, “During a typical fan test, a dozen or more operating points are plotted for pressure and flow rate, and from this data a fan curve is constructed.”

Once a fan curve is determined, it is possible to examine the data and find the operating range for the fans that will meet the thermal requirements of a system. It is also important to note a section in the fan curve, often referred to as the knee of the curve in which the relationship between flow rate and static pressure is no longer easy to predict. There is no longer an easily recognizable, calculable relationship between how a change in one will affect the other.

ATS field application engineer Vineet Barot explained how he analyzed fan curve data, particularly the knee of the curve, in a recent project:

“This is flow rate versus pressure. The more pressure you have in front of a fan, the slower it can pump out the air and this is the curve that determines that.

Fan Laws

Fan operating points on the board, determined by CFD simulations. (Advanced Thermal Solutions, Inc.)

“This little area here is sometime called the knee of the fan curve. Let’s say we’re in this area, the flow rate and pressure is relatively linear, so if I increase my pressure, if I put my hand in front of the fan, the flow rate goes down. If I have no pressure, I have my maximum flow rate. If I increase my pressure then the flow rate goes down. What happens in this part? The same thing. In the knee, a slight increase in pressure, so from .59 to .63, reduces the flow rate quite a bit.

Stratix 10 FPGA

CFD simulations showed that the fans were operating in the “knee” where it is hard to judge the impact of pressure changes on flow rate and vice versa. (Advanced Thermal Solutions, Inc.)

“So, for a 0.1 difference in flow rate (in cubic meters per second) it took 0.4 inches of water pressure difference, whereas here for a 0.1 difference in flow rate it only took a .04 increase in pressure. That’s why there’s a circle there. It’s a danger area because if you’re in that range it gets harder to predict what the flow will be because any pressure-change, any dust build-up, any change in estimated open area might change your flow rate.

Fan Laws

CFD analysis of flow vectors across high-powered components on a PCB. This simulation was part of an examination of fan performance in a system. (Advanced Thermal Solutions, Inc.)

CONCLUSION

While it is important to know the types of fans on the market and manufacturers provide data about the power and operating ranges of each product, it is important for there to be a basic understanding of the laws that govern how fans operate in a system and an ability to examine fan curve data in order to optimize performance.

“Bulk testing of electronics chassis provides the relationship between air flow and pressure drop and determines the fan performance needed to cool a given power load. The fan rating is often a misunderstood issue and published ratings can be somewhat misleading. Knowledge of fan performance curves, and how they are obtained, allows for a more informed decision when selecting a fan. Continued and ever shortening product design cycles demand a ‘get it right the first time’ approach. The upfront use of system curves, fan curves and fan laws can help meet this goal.”

Read more and see examples of fan laws and curves in practice at https://www.qats.com/cms/2013/07/24/how-to-use-fan-curves-and-laws-in-thermal-design.

CLICK HERE FOR PART I

To learn more about Advanced Thermal Solutions, Inc. consulting services, visit www.qats.com or contact ATS at 781.769.2800 or ats-hq@qats.com.