Tag Archives: heat transfer

ATS’ Dr. Camil Ghiu to Present at coolingZONE-13

CZ13_speaker_camil

ATS’ own, Dr. Camil Ghiu, will be presenting “Driving Towards 0.1oC/W In Compact Air Cooled Heat Sinks: Advancements In Flow Management And Air Jet Impingement Cooling” at the Thermal Management Industry International Summit: coolingZONE-13. The Summit will be held in Boston, Massachusetts, October 21-23, 2013.

Considering the widespread use of compact systems, such as the 1U platform, and the drive to reduce costs from the system and deployment view points, air cooling continues to be sought for thermal management of such systems. The decrease in size of the new generation of electronic devices imposes a severe constraint on their incorporated thermal management devices. In this context, the development of low thermal resistance heat sinks (0.1 oC/W) for cooling compact electronics systems (1U form factor) continues to be a challenge for the thermal management community.

Dr. Ghiu’s presentation will present recent developments in designing compact heat sinks using advanced air flow management. Two main approaches will be presented, including heat sink design implementing jet impingement and sectional heat sinks. Both design approaches have been explored at ATS, and the experimental data and simulation results will be presented for further discussion.CZ13_HP

coolingZONE-13 is the premiere engineering conference for the thermal management industry. Leading experts from academia and the electronics cooling industry will present emerging technologies in the most crucial areas of thermal engineering. A wide range of topics will be discussed, including liquid cooling, advanced heat sink and heat pipe design, thermal interface materials, data center cooling and analysis, CFD, and vapor compression cooling. Keynote speakers this year are Dr. Vincent Manno of Olin College, Dr. Marc Hodes of Tufts University and Dr. Kaveh Azar, CEO of Advanced Thermal Solutions, Inc. Additional speakers and exhibitors from Laird, CD-Adapco, Aavid, Cradle-CFD, Schneider Electric, and Future Facilities will also be presenting at the conference.

Download the Brochure

Register Now

Latest Qpedia Now Available for Download

Qpedia Thermal eMagazine June 2013

Qpedia Thermal eMagazine June 2013

Qpedia Thermal eMagazine, Volume 7, Issue 6, has just been released and can be downloaded at: http://www.qats.com/Qpedia-Thermal-eMagazine/Back-Issues.

This month’s featured articles include:

Enhancing Heat Sink Performance Using Thermoelectric Coolers

With the increase in the power dissipation of components and the parallel reduction of their size, engineers and researchers across the globe have been predicting that the era of air cooling might come to an end. Even though in some applications, with very high power dissipations such as IGBTs, air cooling may not be adequate and liquid cooling is a must; air cooling will continue to be the first choice for most electronic cooling applications for many years to come. Advances in air cooling continue to extend its use and the implementation of thermoelectric coolers (TECs) in heat sink applications is one such effort.

Immersion Liquid Cooling for Servers in Data Centers

Data center designers and operators have invented many ways to improve the data center’s thermal efficiency, such as optimizing the rack layout and air conditioner location, separating cold aisles and hot aisles, optimizing the configuration of pipes and cables in under-floor plenum, introducing liquid cooling to high-power severs. While the above methods can improve the data center heat load management, they cannot dramatically reduce the Power Usage Effectiveness (PUE). This article reviews two relatively new solutions: active single-phase immersion cooling technology proposed by Green Revolution Cooling (GRC) and a passive two-phase immersion cooling technology proposed by the 3M Company.

Industry Developments: Piezoelectric Cooling

Piezoelectric fans and jets must overcome various materials, thermal and mechanical challenges to become widely used in electronics cooling, but because they consume just 1/150 of the electricity of circular fans, run with little noise and have no parts that will wear out, they remain of great interest. In this article, a number of issues are addressed, including the inverse effect of the piezoelectric phenomena and dual piezoelectric cooling jets.

Technology Review: Innovative Cold Plate Designs, 2007 – 2012

In this issue our spotlight is on innovative cold plate designs. There is much discussion about its deployment in the electronics industry, and these patents show some of the salient features that are the focus of different inventors.

& Cooling News featuring the latest product releases and buzz from around the electronics cooling industry.

Download the issue now.

Not a Qpedia subscriber? Subscribe Now for free at: http://www.qats.com/Qpedia-Thermal-eMagazine/Subscribe-to-Qpedia and see why over 18,000 engineers read Qpedia.

Did you know Qpedia also publishes a book series? The five volume set contains 248 in-depth articles, researched and written by veteran engineers. They address the most critical areas of electronics cooling, with a wide spectrum of topics and thorough technical explanation. Order Now.

How to Use Fan Curves and Laws in Thermal Design

In today’s electronics industry, there is a constant and well documented push to higher powered components, tighter grouping of devices, and overall increased system thermal dissipation. The higher dissipation must be managed effectively to ensure long term reliability of the system.

With forced convection being the dominant mode of electronics cooling, more efficient heat sinks are often used for cooling these increased thermal loads. But, they are only half the solution. Due to volumetric constraints, it may not be possible to design an adequate heat sink for a given component. A large amount of air preheating may occur if multiple components lie in the flow path. The increased ambient temperature resulting from this preheated air often brings the need for a larger heat sink, but the space may not be available.

The solution to higher power levels and decreasing heat sink space is to increase the system’s air flow rate. A boost in flow rate has a twofold benefit: first, it lowers the thermal resistance of the heat sink, which reduces the temperature difference from junction to ambient. Secondly, it reduces the overall temperature rise in the chassis. The reduced temperature rise allows downstream components to suffer less preheating and operate at lower ambient temperatures.

This direct relationship between air velocity and component temperature indicates the importance of understanding how fans behave in electronics cooling.

System Curve

Prior to selecting any fan it is important to characterize the overall system with respect to air flow and pressure drop. For example, a tightly packed 1U chassis will require a much different fan configuration than a larger desktop one, even if both systems use the same CPU. In the 1U chassis, components are spaced very tightly and exhibit a large resistance to flow. This requires a fan with a high pressure head. A benefit of the 1U chassis design is less bypass flow, reducing the need for larger volumetric flow rate. In an ATX style desktop chassis the requirements are very much the opposite. There is typically much more open space in the ATX chassis, which lowers the chassis pressure drop. The widely spaced components create a less efficient flow path, and thus a larger volumetric flow is needed to ensure adequate cooling of all components.

Figure 1. Typical Overlay of a System Curve and Fan Curve

Fan Curve

A fan curve example is shown in Figure 1. Point A is the no flow point of the fan curve, where the fan is producing the highest pressure possible. Next on the curve is the stall region of the fan, Point B, which is an unstable operating region and should be avoided. From point C to point D is the low pressure region of the fan curve. This is a stable area of fan operation and should be the design goal. It is best to select a fan that operates to the higher flow point of this region to improve fan efficiency and compensate for filter clogging.

The system pressure curve can then be compared to a specific fan curve to determine if the fan is adequate. To compare fan curves from different manufacturers, it is important to follow a testing standard. For electronics applications, the relevant standard is the AMCA 210-99/ ASHRAE 51-1999 test guidelines.

Figure 2a. AMCA Fan Testing Chamber

The AMCA fan testing chamber, shown in Figure 2a, consists of a supply fan, a variable blast gate, two test chambers, flow nozzles and an opening to place the test fan. A commercialized testing module from Advanced Thermal Solutions, Inc. is shown in 2b.

During a typical fan test, a dozen or more operating points are plotted for pressure and flow rate, and from this data a fan curve is constructed. To obtain the highest pressure rating of the fan, the blast gate shown in Figure 2a, is closed to ensure zero flow while the fan is running. The chamber pressure is then read from the static pressure manometer to obtain the maximum pressure rating of the fan. The blast gate is then slightly opened in successive steps to obtain additional operating points. Finally, the maximum flow capability of the fan is found by opening the blast gate completely and running the supply fan. The supply fan ensures the secondary chamber is operating at atmospheric pressure, which removes the flow losses in the system.

Figure 2b. FCM-100 Fan Characterization Module from Advanced Thermal Solutions, Inc.

The operating pressure of the fan curve is found by taking measurements from a static manometer. The volumetric flow rate, Q, is found by measuring the pressure drop across an AMCA nozzle (Figure 3) using a differential manometer. The flow rate through an AMCA nozzle is a function of its size and differential pressure as shown in the following equation.

In contrast, the FCM-100 is void of any nozzles and works based on volumetric flow rate measurement using the ATVS technology flow sensing system. It is compact, portable and capable of characterizing single fans or fan trays.

Figure 3. Various AMCA Nozzles (CTS, Inc.)

Air Flow

Fan Laws

Fan laws are a set of equations applied to geometrically identical fans for scaling and performance calculations.

Published fan laws apply to applications where a fan’s air flow rate and pressure are independent of the Reynolds number. In some applications, however, fan performance is not independent and thus the change in Reynolds number should be incorporated into the equation. To determine if the Reynolds number needs to be considered, it must first be calculated.

According to AMCA specifications, an axial fan’s minimum Reynolds number is 2.0×106 When the calculated Reynolds number is above this value, its effects can be ignored.

Fan Law Application

During a product’s life cycle a redesign may be carried out which replaces older components with new, higher powered ones. Due to the resulting higher heat flux, increased cooling is often needed to maintain adequate junction temperatures and reduce temperature rise within the system.

Consider for example a telecom chassis using a single 120 mm fan for cooling. The maximum acceptable temperature rise in the box is 15°C. The chassis dissipates 800 W, but a board redesign will increase the power to 1200 W. The current 120 mm fan produces a 3³/min flow rate at 3000 RPM using 8 W of power. How do we calculate the requirements of a substitute fan for the higher powered system?

Next, calculate the change in RPM needed:

Thus, to meet this example’s cooling requirement for 1200 W, a fan is needed with a 4³/min flow rate, 4,000 RPM speed and 18.9 W of power. Note that the system power, flow rate and fan RPM all increased in a linear fashion from those in the original system. However, the fan power increased by nearly a factor of three.

Summary

Bulk testing of electronics chassis provides the relationship between air flow and pressure drop and determines the fan performance needed to cool a given power load. The fan rating is often a misunderstood issue and published ratings can be somewhat misleading. Knowledge of fan performance curves, and how they are obtained, allows for a more informed decision when selecting a fan. Continued and ever shortening product design cycles demand a “get it right the first time” approach. The upfront use of system curves, fan curves and fan laws can help meet this goal.

References:
1. Ellison, G., Fan Cooled Enclosure Analysis Using a First Order Method, Electronics Cooling, October 1995.
2. Daly, W., Practical Guide to Fan Engineering, Woods of Colchester, Ltd, 1992.
3. Turner, M., All You Need to Know About Fans, Electronics Cooling, May 1996.
4. Certified Ratings Program – Product Rating Manual for Fan Air Performance, AMCA 211-05 (Rev. 9/07).

This article was first published in Qpedia. To buy the complete Qpedia book set, please visit: http://www.qats.com/eShop/Qpedia

To learn more about Fan Characterization and the FCM-100, please visit: http://www.qats.com/Products/Specialty-Instruments/Fan-Characterization

The New Qpedia Thermal eMagazine is Out

Qpedia Thermal eMagazine, Volume 7, Issue 4, has just been released and can be downloaded at: http://www.qats.com/Qpedia-Thermal-eMagazine/Back-Issues.

Featured articles in this issue include:

Dropwise Condensation in Vapor Chambers
Considerable attention has been devoted in the past to the evaporation process taking place in a vapor chamber. However, increased heat fluxes at the condensation end have prompted efforts to improve the condensation performance of the vapor chambers. This article presents a review of a novel method for improving the thermal performance of a vapor chamber condensing section by using special surfaces promoting dropwise condensation.

 

Heat Sink Manufacturing Using Metal Injection Molding

Using Metal Injection Molding It is only in the last few years that metal injection molding (MIM) has gained a foothold in the thermal community and its salient advantages have become more evident. The MIM process allows intricate features to be added into the heat sink design to boost thermal performance and its production process is very scalable compared with machining. Injection molding enables complex parts to be formed as easily as simple geometries, thereby allowing increased design freedom.  This article explore the merits of copper material in the MIM process.

 

Industry Developments: Thermoelectric Modules and Coolers

Thermoelectric modules (TEMs) are rugged, reliable and quiet devices that serve as heat pumps. The real heat-moving components inside TEMs are thermoelectric coolers or TECs. These are solid-state heat pumps and are designed for applications where temperature stabilization, temperature cycling, or cooling below ambient, are required. Today, TEMs are used in electro-optics applications, such as the cooling and stabilizing of laser diodes, IR detectors, cameras (charge coupled device), microprocessors, blood analyzers and optical switches. This article explores some of the latest developments in these devices.

 

Technology Review: Reducing Thermal Spreading Resistance in Heat Sinks

In this issue our spotlight is on reducing spreading resistance in heat sinks. There is much discussion about how this phenomenon can be achieved, and these patents show some of the salient features that are the focus of different inventors.

 

Cooling News featuring the latest product releases and buzz from around the electronics cooling industry.

 

Download the issue now.

 

Not a Qpedia subscriber? Subscribe Now for free at: http://www.qats.com/Qpedia-Thermal-eMagazine/Subscribe-to-Qpedia and see why over 18,000 engineers read Qpedia.

New Consulting Project Subscription Plan

ATS has released a Consulting Project Subscription Plan (CPSP) for engineering services. From our corporate headquarters in Norwood, Massachusetts,we offers comprehensive thermal management analysis and design services for the telecommunications, medical, military, defense, aerospace, automotive, and embedded computing industries. The new plan allows ATS engineers to become an extension of your team for a pre-determined amount of hours, providing expert thermal and mechanical engineering consultation, design, simulation, testing and validation.

ATS Design Services

Services include Design, Simulation, Testing, Analysis & Prototyping

The CPSP includes the use of ATS thermal lab facilities and covers all projects approved by an authorized representative of subscribed customers. ATS thermal management analysis and design services encompass both experimental and computational simulations using proprietary tools and computational fluid dynamics software packages such as FLOTHERM and CFdesign.

Thermal Testing & Analysis

Thermal Testing & Analysis

The new subscription plan gives customers priority access to ATS engineering and manufacturing resources for all chip, board, enclosure, and system related projects. ATS studies the full packaging domain, including components, circuit boards (PCBs), shelves, chassis, and system packaging.

Consulting capabilities include:

– heat sink, board and fan characterization

– heat sink design and optimization

– PCB & fan tray design and optimization

– liquid cooling design

– prototyping of heat sinks and complete cooling systems

– wind tunnel testing of components, PCBs, chassis and enclosures

ATS offers rapid prototyping of machined parts and cooling systems from its US facilities. Sheet metal fabrication and cut heat sink prototypes are quickly provided from international partners.

Liquid Crystal Thermography

Liquid Crystal Thermography

ATS believes that customers who wish to remain competitive should consider a design-to-suit opportunity solution first. Contrary to common perception, this proves to be less expensive to the customer in the long run, because of the ensuing gain in product efficiency and compatibility. Working side-by-side with customers worldwide, ATS engineers provide tailored solutions to thermal and mechanical packaging challenges on real projects with real schedules.

To learn more about the consulting project subscription plan, call 781-769-2800, email ats-hq@qats.com, or visit www.qats.com.